Hirschmann BOBCAT 8xFE, 4xSFP, PoE
BRS32-0804OOOO-SPCZ99HHSEAXX.X.XX
Product description
Description
Managed Industrial Switch for DIN Rail, fanless design Fast Ethernet, Gigabit uplink type , power sourcing equipment in accordance with IEEE 802.3at (PoE+ inline power) , max. PoE power 240 W
Software Version
HiOS 10.3.02
Configurator Part Number
942170999
Port Type and Quantity
12 Ports in total: 8x 10/100BASE TX / RJ45; 4x 100/1000Mbit/s fiber ; 8 x PoE(+) Ports (phantom power) ; 1. Uplink: 2 x SFP Slot (100/1000 Mbit/s) ; 2. Uplink: 2 x SFP Slot (100/1000 Mbit/s)
More Interfaces
Power supply/signaling contact
1 x plug-in terminal block, 6-pin
Local Management and Device Replacement
USB-C
Network size - length of cable
Twisted pair (TP)
0 - 100 m
Single mode fiber (SM) 9/125 µm
see SFP fiber modules see SFP fiber modules
Single mode fiber (LH) 9/125 µm (long haul transceiver)
see SFP fiber modules see SFP fiber modules
Multimode fiber (MM) 50/125 µm
see SFP fiber modules see SFP fiber modules
Multimode fiber (MM) 62.5/125 µm
see SFP fiber modules see SFP fiber modules
Network size - cascadibility
Line - / star topology
any
Power requirements
Operating Voltage
2 x (48 VDC (PoE)/ 54 VDC (PoE+))
Power consumption
max. 250 W with 240W PoE
Power output in BTU (IT)/h
max. 34
Software
Switching
CoS Queue Management, Egress Interface Shaping, Fast Aging, Flow Control (802.3X), Forward unknown multicast to query ports per vlan, GARP Multicast Registration Protocol (GMRP), GARP VLAN Registration Protocol (GVRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Independent VLAN Learning, Ingress Storm Protection, Interface Trust Mode, Jumbo Frames, Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Multiple VLAN Registration Protocol (MVRP), QoS / Port Prioritization (802.1D/p), Queue-Shaping / Max. Queue Bandwidth, Static Unicast/Multicast Address Entries, TOS/DSCP Prioritization, TSN 802.1Qbv Support on interfaces 1/1 - 1/3., Unknown Multicast Filtering, VLAN (802.1Q), Voice VLAN, Private VLAN
Redundancy
HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2) - Redundancy Client, Media Redundancy Protocol (MRP) (IEC62439-2) - Redundancy Manager, Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards, HIPER-Ring over Link Aggregation, MRP over Link Aggregation, MSTP (802.1Q), Sub Ring Manager
Management
Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, IPv6 Management, Traps, SNMP v1/v2/v3, SNMPv3 Traps, Telnet, DNS Client, ITxPT Module Inventory, OPC-UA Server, Service Discovery (bonjour), SNMPv1/v2 Read-Only
Diagnostics
Configuration Check Dialog, Copper Cable Test, Device Status Indication, Duplex Mismatch Detection, LEDs, Link Flap Detection, Link Speed and Duplex Monitoring, MAC Notification, Management Address Conflict Detection, Overload Detection, Persistent Logging on ACA, Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, Port Monitoring with Auto-Disable, RMON (1,2,3,9), Self-Tests on Cold Start, SFP Management, Signal Contact, Switch Dump, Syslog, System Information, TCPDump, Email Notification, Loop Protection, RSPAN, SFLOW
Configuration
Auto Disable, AutoConfiguration Adapter ACA21/22 (USB), Automatic Configuration Undo (roll-back), Backup config on a remote server when saving, BOOTP/DHCP Client with Auto-Configuration, Clear config but keep IP settings, CLI script handling over ENVM at boot, CLI Scripting, Command Line Interface (CLI), Configuration Fingerprint, Context-sensitive Help, DHCP Relay with Option 82, DHCP Server: per Port, DHCP Server: Pools per VLAN, Full-featured MIB Support, HiDiscovery, HTML5 based Management, USB-C Management support, XML-based Configuration File, Interface Shutdown via Tracking
Security
Access to Management restricted by VLAN, Appropriate Use Banner, Audit Trail, Basic ACL, CLI Logging, Configurable Number of Login Attempts, Configurable Password Policy, Denial-of-Service Prevention, Device Security Indication, DoS Prevention Drop Counter, Guest/unauthenticated VLAN, HTTPS Certificate Management, Ingress VLAN-based ACL, Integrated Authentication Server (IAS), Local User Management, MAC-based Port Security, Multiple Privilege Levels, Password change on first login, Port-based Access Control with 802.1X, RADIUS Client, RADIUS VLAN Assignment, Remote Authentication via RADIUS, Restricted Management Access, Secure Boot, Signed Firmware Images, SNMP Logging, User Account Locking, VLAN-based ACL, ACL Flow-based Limiting, DHCP Snooping, Dynamic ARP Inspection, Format options for MAC authentication bypass, Ingress IPv4-based ACL, Ingress MAC-based ACL, IP Source Guard, LDAP, MAC Authentication Bypass, MACSec Support, Multi-Client Authentication per Port, TACACS+ Client, Time-based ACL
Time synchronisation
802.1AS, 802.1AS-2020, BC with Up to 8 Sync / s, Buffered Real Time Clock, PTPv2 Boundary Clock, PTPv2 Transparent Clock two-step, SNTP Client, SNTP Server
Industrial Profiles
EtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), Modbus TCP, PROFINET Protocol
Miscellaneous
Digital IO Management, Manual Cable Crossing, Port Power Down, , PoE (802.3af), PoE+ (802.3at), PoE+ Manual Power Management, PoE Fast Startup
Ambient conditions
MTBF (Telecordia SR-332 Issue 3) @ 25°C
3 409 257 h
Operating temperature
0-+60
Relative humidity (non-condensing)
1- 95 %
Mechanical construction
Dimensions (WxHxD)
73 mm x 138 mm x 115 mm
Weight
550 g
Housing
PC-ABS
Mount Type
DIN Rail
Protection class
IP30
Mechanical stability
IEC 60068-2-6 vibration
5 Hz ... 8,4 Hz with 3,5 mm amplitude; 2 Hz ... 13,2 Hz with 1 mm amplitude; 8,4 Hz ... 200 Hz with 1 g; 13,2 Hz ... 100 Hz with 0,7 g
IEC 60068-2-27 shock
15 g, 11 ms duration
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 2 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth) and 1 kV (line/line); data line: 2 kV
EN 61000-4-6 Conducted Immunity
10 V (150 kHz-80 MHz)
EMC emitted immunity
EN 55022
EN 55032 Class A
FCC CFR47 Part 15
FCC 47CFR Part 15, Class A
Approvals
Basis Standard
CE, FCC, EN61131, EN62368-1
Reliability
Guarantee
60 months (please refer to the <a href="https://assets.belden.com/m/1424ddb7a3280e7a/original/Hirschmann-Automation-and-Control-GmbH-Terms-of-Guarantee.pdf"
terms of guarantee </a
for detailed information)
Scope of delivery and accessories
Accessories
AutoConfiguration Adapter ACA22-USB-C (EEC) 942239001; 6-pin terminal block with screw lock (50 pieces) 943 845-013; 2-pin terminal block with screw lock (50 pieces) 943 845-009; Industrial HiVision Network Management Software 943 156-xxx
Scope of delivery
1 × Device, 1 × Safety and general information sheet, 1 × Terminal block for supply voltage and signal contact, 1 × Terminal block for the digital input depending on device variant, 2 × Ferrites with key depending on device variant
Further Instructions
Product Documentation
https://www.doc.hirschmann.com/index.html
Certificates
https://www.doc.hirschmann.com/certificates.html
Software Download
https://my.belden.com/s/downloads
Tilbehør
Hirschmann Power Supply RPS 30
Terminal kabel RJ11 til DSUB-9
Alternativer
Artikler
Antall artikler funnet:
Kundcenter
Til norsk shop
Logga in
Inga varor i varukorgen
Ingen varer i ordreboka
produkt
produkter
(
)
(
)
(
)
Checka ut
×
Aktiv leveringsdato
Leveringsdatoer
Kundvagn
varor i kundvagnen
Klikk her for å se alle
Handlevognen er tom.
Søk
Industriell IT
Her er du nå:
Adeptor
>
Industriell IT
>
Nätverk Industri
>
BOBCAT
>
BRS30
>
Hirschmann BOBCAT 8xFE, 4xSFP, PoE
Hirschmann BOBCAT 8xFE, 4xSFP, PoE
BRS32-0804OOOO-SPCZ99HHSEAXX.X.XX
Varunummer:
BRS32-0804OOOO-04
Förfrågan
Beskrivning
Dokumentasjon
Product description
Description
Managed Industrial Switch for DIN Rail, fanless design Fast Ethernet, Gigabit uplink type , power sourcing equipment in accordance with IEEE 802.3at (PoE+ inline power) , max. PoE power 240 W
Software Version
HiOS 10.3.02
Configurator Part Number
942170999
Port Type and Quantity
12 Ports in total: 8x 10/100BASE TX / RJ45; 4x 100/1000Mbit/s fiber ; 8 x PoE(+) Ports (phantom power) ; 1. Uplink: 2 x SFP Slot (100/1000 Mbit/s) ; 2. Uplink: 2 x SFP Slot (100/1000 Mbit/s)
More Interfaces
Power supply/signaling contact
1 x plug-in terminal block, 6-pin
Local Management and Device Replacement
USB-C
Network size - length of cable
Twisted pair (TP)
0 - 100 m
Single mode fiber (SM) 9/125 µm
see SFP fiber modules see SFP fiber modules
Single mode fiber (LH) 9/125 µm (long haul transceiver)
see SFP fiber modules see SFP fiber modules
Multimode fiber (MM) 50/125 µm
see SFP fiber modules see SFP fiber modules
Multimode fiber (MM) 62.5/125 µm
see SFP fiber modules see SFP fiber modules
Network size - cascadibility
Line - / star topology
any
Power requirements
Operating Voltage
2 x (48 VDC (PoE)/ 54 VDC (PoE+))
Power consumption
max. 250 W with 240W PoE
Power output in BTU (IT)/h
max. 34
Software
Switching
CoS Queue Management, Egress Interface Shaping, Fast Aging, Flow Control (802.3X), Forward unknown multicast to query ports per vlan, GARP Multicast Registration Protocol (GMRP), GARP VLAN Registration Protocol (GVRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Independent VLAN Learning, Ingress Storm Protection, Interface Trust Mode, Jumbo Frames, Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Multiple VLAN Registration Protocol (MVRP), QoS / Port Prioritization (802.1D/p), Queue-Shaping / Max. Queue Bandwidth, Static Unicast/Multicast Address Entries, TOS/DSCP Prioritization, TSN 802.1Qbv Support on interfaces 1/1 - 1/3., Unknown Multicast Filtering, VLAN (802.1Q), Voice VLAN, Private VLAN
Redundancy
HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2) - Redundancy Client, Media Redundancy Protocol (MRP) (IEC62439-2) - Redundancy Manager, Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards, HIPER-Ring over Link Aggregation, MRP over Link Aggregation, MSTP (802.1Q), Sub Ring Manager
Management
Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, IPv6 Management, Traps, SNMP v1/v2/v3, SNMPv3 Traps, Telnet, DNS Client, ITxPT Module Inventory, OPC-UA Server, Service Discovery (bonjour), SNMPv1/v2 Read-Only
Diagnostics
Configuration Check Dialog, Copper Cable Test, Device Status Indication, Duplex Mismatch Detection, LEDs, Link Flap Detection, Link Speed and Duplex Monitoring, MAC Notification, Management Address Conflict Detection, Overload Detection, Persistent Logging on ACA, Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, Port Monitoring with Auto-Disable, RMON (1,2,3,9), Self-Tests on Cold Start, SFP Management, Signal Contact, Switch Dump, Syslog, System Information, TCPDump, Email Notification, Loop Protection, RSPAN, SFLOW
Configuration
Auto Disable, AutoConfiguration Adapter ACA21/22 (USB), Automatic Configuration Undo (roll-back), Backup config on a remote server when saving, BOOTP/DHCP Client with Auto-Configuration, Clear config but keep IP settings, CLI script handling over ENVM at boot, CLI Scripting, Command Line Interface (CLI), Configuration Fingerprint, Context-sensitive Help, DHCP Relay with Option 82, DHCP Server: per Port, DHCP Server: Pools per VLAN, Full-featured MIB Support, HiDiscovery, HTML5 based Management, USB-C Management support, XML-based Configuration File, Interface Shutdown via Tracking
Security
Access to Management restricted by VLAN, Appropriate Use Banner, Audit Trail, Basic ACL, CLI Logging, Configurable Number of Login Attempts, Configurable Password Policy, Denial-of-Service Prevention, Device Security Indication, DoS Prevention Drop Counter, Guest/unauthenticated VLAN, HTTPS Certificate Management, Ingress VLAN-based ACL, Integrated Authentication Server (IAS), Local User Management, MAC-based Port Security, Multiple Privilege Levels, Password change on first login, Port-based Access Control with 802.1X, RADIUS Client, RADIUS VLAN Assignment, Remote Authentication via RADIUS, Restricted Management Access, Secure Boot, Signed Firmware Images, SNMP Logging, User Account Locking, VLAN-based ACL, ACL Flow-based Limiting, DHCP Snooping, Dynamic ARP Inspection, Format options for MAC authentication bypass, Ingress IPv4-based ACL, Ingress MAC-based ACL, IP Source Guard, LDAP, MAC Authentication Bypass, MACSec Support, Multi-Client Authentication per Port, TACACS+ Client, Time-based ACL
Time synchronisation
802.1AS, 802.1AS-2020, BC with Up to 8 Sync / s, Buffered Real Time Clock, PTPv2 Boundary Clock, PTPv2 Transparent Clock two-step, SNTP Client, SNTP Server
Industrial Profiles
EtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), Modbus TCP, PROFINET Protocol
Miscellaneous
Digital IO Management, Manual Cable Crossing, Port Power Down, , PoE (802.3af), PoE+ (802.3at), PoE+ Manual Power Management, PoE Fast Startup
Ambient conditions
MTBF (Telecordia SR-332 Issue 3) @ 25°C
3 409 257 h
Operating temperature
0-+60
Relative humidity (non-condensing)
1- 95 %
Mechanical construction
Dimensions (WxHxD)
73 mm x 138 mm x 115 mm
Weight
550 g
Housing
PC-ABS
Mount Type
DIN Rail
Protection class
IP30
Mechanical stability
IEC 60068-2-6 vibration
5 Hz ... 8,4 Hz with 3,5 mm amplitude; 2 Hz ... 13,2 Hz with 1 mm amplitude; 8,4 Hz ... 200 Hz with 1 g; 13,2 Hz ... 100 Hz with 0,7 g
IEC 60068-2-27 shock
15 g, 11 ms duration
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 2 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth) and 1 kV (line/line); data line: 2 kV
EN 61000-4-6 Conducted Immunity
10 V (150 kHz-80 MHz)
EMC emitted immunity
EN 55022
EN 55032 Class A
FCC CFR47 Part 15
FCC 47CFR Part 15, Class A
Approvals
Basis Standard
CE, FCC, EN61131, EN62368-1
Reliability
Guarantee
60 months (please refer to the <a href="https://assets.belden.com/m/1424ddb7a3280e7a/original/Hirschmann-Automation-and-Control-GmbH-Terms-of-Guarantee.pdf"
terms of guarantee </a
for detailed information)
Scope of delivery and accessories
Accessories
AutoConfiguration Adapter ACA22-USB-C (EEC) 942239001; 6-pin terminal block with screw lock (50 pieces) 943 845-013; 2-pin terminal block with screw lock (50 pieces) 943 845-009; Industrial HiVision Network Management Software 943 156-xxx
Scope of delivery
1 × Device, 1 × Safety and general information sheet, 1 × Terminal block for supply voltage and signal contact, 1 × Terminal block for the digital input depending on device variant, 2 × Ferrites with key depending on device variant
Further Instructions
Product Documentation
https://www.doc.hirschmann.com/index.html
Certificates
https://www.doc.hirschmann.com/certificates.html
Software Download
https://my.belden.com/s/downloads
Produsent
Support
BRS32-0804OOOO-SPCZ99HHSEAXXXXX_techdata.pdf
Tillbehör
Hirschmann Power Supply RPS 30
230 VAC prim., 24 VDC sek., 1.3A, 30W
Förfrågan
Terminal kabel RJ11 til DSUB-9
Lengde 5 meter
Förfrågan
Copyright © 2025 Adeptor AS - All rights reserved
Affärssystem
och
webshop
är levererat av
Multicase™ Norge AS
Logga in / Ny kund
Registrer meg som kunde
Kundcenter
Til norsk shop
Tilbake